Hubble Kit – SVAN 977 Weatherproof System

An ideal solution to anyone who needs a powerful yet small and lightweight sound meter system that is capable of being used both indoors and outdoors.

The SVAN 977 Weatherproof System Features: –

  • Over 192 Hours Run Time
  • ‘Hot-Swap’ for battery replacement in the field without turning off the sound meter
  • Tough, weatherproof case withstanding 900Kg loads
  • External weatherproof connectors
  • Optional plug-in weather-proof power supply giving an impressive 40 day run time (approximate)

SA 279

The SA 279 outdoor kit protects the SVAN 979 preamplifier and microphone from the weather conditions. The use of the outdoor kit requires the extension cable between the instrument and its preamplifier. The SA 279 is made of lightweight materials and is easy to install on a tripod. The solution is recommended for short term and semi-permanent noise measurements in the environment.

 

SA 277

The SA 277 outdoor kit protects the SVAN 977 preamplifier and microphone from the weather conditions. The use of the outdoor kit requires the extension cable between the instrument and its preamplifier. The SA 277 is made of lightweight materials and is easy to install on a tripod. The solution is recommended in short term and semi-permanent noise measurements in the environment.

 

SV 973

SV 973 is a Class 2 sound level meter with a wide frequency range up to 10 kHz. The unique feature of the SV 973 is the microphone in MEMS technology with a lifetime warranty. The meter’s measurement range from 25 to 128 dB enables its use in industrial and environmental noise measurements.

For measurements of noise at work, the intelligent sound exposure meter function limits the frequency range to 10 kHz and shifts the dynamic measuring range of sound level meter to 141 dB Peak. The instrument is easily calibrated in the field using an acoustic calibrator as the calibration begins automatically when the microphone is inserted into the calibrator. The SV 973 can measure broad-band results with all the necessary weighting filters as well as 1/1 octave or 1/3 octave band filters. Audio events recording function works together with sound level meter mode. The data are stored on built-in 8 GB memory and can be easily downloaded to a PC using the Supervisor or SVANPC++ software.

 

SA 271

The SA 271 outdoor kit protects the SVAN 971 pre-amplifier and microphone from the weather conditions. The use of the outdoor kit requires the extension cable between the instrument and its pre-amplifier. The SA 271 is made of lightweight materials and is easy to install on a tripod. The solution is recommended in short term and semi-permanent noise measurements in the environment.

 

 

 

SV 307

The SV 307 is a new Noise Monitoring Station dedicated for permanent noise monitoring. The SV 307 integrates Class 1 sound level meter with a modem in the removable waterproof housing. The SV 307 is equipped with a new MEMS microphone with a life-time warranty. The measurement data is stored on the microSD card.

The SV 307 is designed for permanent noise monitoring, it has been equipped with a patented double self-system check: an inbuilt reference sound source producing 100dB at 1 kHz plus real-time check based on reference microphone.

The waterproof housing of SV307 can be removed to get an access to the user interface with a colour display and keypad. The SV 307 has an internal Li-Ion battery and interface for connecting solar panels. A waterproof mains adaptor for charging the battery and powering the station is also included.

SvanNET cloud service monitors the wireless communication, powering and access to the SV 307 data. The scope of the basic SvanNET can be extended with multipoint project management that offers data storage in the cloud, data sharing, advanced alarming and reporting features. SvanNET is an on-line solution which means it doesn’t require software installation and is accessible through a web browser. The responsive design enables use of SvanNET on various devices such as smartphones or tablets.

SV 25S

SV 25S Microphone In Real Ear (MIRE) is dedicated to measurements at the entrance to the human ear. This measurement technique is used when standard noise dosimetery is not applicable, for instance in call centres.
The SV 25S microphone works with SV102+ or SV102A+ instruments. The microphone adaptor is adjustable so the microphone probe can be installed in a correct position at the entrance of the ear.

SA 104-1

The SA 104-1 docking station supports simultaneous battery charging and data download from SV 104IS noise dosimeter . The instrument is positioned on the docking station with a holders system that ensures the correct position for battery charging. The SA 104-5 uses the mini USB port for battery charging and connection with PC. The data download is handled by the infra-red interface. The status of the dosimeter battery is indicated by the LED diode located next to the handle system.

SA 104-5

The SV104IS noise dosimeter requires usage of docking station for battery charging and measurement data download. The SA 104-5 docking station supports simultaneous battery charging and data download from up to five dosimeters. The instrument is positioned on the docking station with a holders system that ensures the correct position for battery charging. The SA 104-5 uses the external power supply for battery charging and USB cable for connection with PC. The data download from noise dosimeters is handled by the infra-red interface. The status of the dosimeter battery is indicated by the LED diodes located next to the handle system.

SV 102A+

SV 102A+ Class 1 Dual Channel Dosimeter is presenting new approach to occupational health and safety acoustic monitoring task. This dosimeter can be also used as a dual-channel Class1 sound level meter and real-time 1/1 octave & 1/3 octave analyser.
Octave analysis, providing direct data for the design of the ear-protectors, together with Audio Events Recording (AER) function show the new reference standard on acoustic dose measurement field. The binaural dose measurement and octave analysis are simultaneously performed by this compact-size instrument. Three acoustic profiles per channel allow parallel measurements with independently defined filters and RMS detector time constants. Advanced time-history logging in each profile, together with spectra saving and Audio Events Recording provide a complete information about the measured signal. Data is stored in large 8 GB memory and can be easily downloaded to any PC using USB interface and Supervisor software.
The small and compact SV 15 preamplifier together with special mounting clip and dedicated headband enables an easy attachment of the microphone in extremely short distance to human ears. Calibration by measurement can be easily performed by direct usage of common acoustic calibrators.
SV 102A+ is also able to perform the measurement inside human ear – with the usage of SV 25S – smart microphone with an automatic calibration function (TEDS). The SV 102A together with SV 25S are designed for individual real-world test of the earmuffs noise reduction ratio by means of MIRE technique (Microphone-In-Real-Ear)-measurements under headphones or earmuffs. With a special adaptor, SV 25S can be also calibrated with available acoustic calibrators.

Contact Us

Our calibration lab is closing for Christmas on the 10th December!

Discuss your requirements